首页|基于改进重要度的约简算法在区域配电网故障诊断中的应用

基于改进重要度的约简算法在区域配电网故障诊断中的应用

扫码查看
配电网发生故障后,保护装置拒动或误动使得大量不完备信息涌入调度中心,这些缺失、冗余、错误的信息将可能导致诊断结果的不准确甚至严重错误.在原有经典依赖度算法基础上,提出一种基于改进的重要度约简算法,对信息不完备、冗余、错误的决策表进行约简.约简后的决策表决策属性与原始决策表一致,而条件属性较原始决策表减少.最后结合区域配电网算例,对配电网发生故障后的不一致决策表进行重要度的计算,采用基于改进重要度的约简算法对原始决策表进行约简,得到去除冗余属性后的决策表,解决不一致决策表因信息缺失造成决策属性误判的问题,验证算法正确性.
AN IMPROVED IMPORTANCE REDUCTION ALGORITHM APPLICATION IN REGIONAL POWER GRID FAULT DIAGNOSIS
A large number of incomplete information will flood into the dispatching center due to the refusal or misoperation of protec-tion devices after the failure of distribution network.These missing,redundant and wrong information may lead to inaccurate diagnosis results or even serious errors.Based on the original classical dependency algorithm,this thesis proposes an improved importance reduc-tion algorithm to reduce the decision table with incomplete,redundant and wrong information.The decision attributes of the reduced de-cision table are consistent with the original decision table,but the conditional attributes are less than the original decision table.Finally,it calculates the importance of inconsistent decision table after distribution network failure,and reduces the original decision table by using the reduction algorithm of improved importance to get the decision table after removing redundant attributes with an example of re-gional distribution network,which solves the problem of misjudgment of decision attributes caused by lack of information in inconsistent decision table and verifies the correctness of the algorithm.

importanceattribute reductionregional power gridfault diagnosis

杜瑞娟

展开 >

南阳理工学院智能制造学院 河南 南阳 473004

重要度 属性约简 区域电网 故障诊断

2024

南阳理工学院学报
南阳理工学院

南阳理工学院学报

CHSSCD
影响因子:0.178
ISSN:1674-5132
年,卷(期):2024.16(4)