Based on standard κ-ε model and using FLUENT,the simulation of internal flow field in series pulsed nozzle was carried out by changing chamber length.The velocity distribution was obtained.The simulation results indicated that there was an optimized chamber length to get maximum outlet velocity.Similar results were also obtained by experiment.