青海电力2024,Vol.43Issue(3) :49-52.DOI:10.15919/j.cnki.qhep.2024.03.010

调相机顶轴油系统典型异常分析及优化处理措施

Analysis of the Typical Abnormal of the Pump Oil System of the Condenser and the Optimal Treatment Measures

李富荣 马涛 金顺安
青海电力2024,Vol.43Issue(3) :49-52.DOI:10.15919/j.cnki.qhep.2024.03.010

调相机顶轴油系统典型异常分析及优化处理措施

Analysis of the Typical Abnormal of the Pump Oil System of the Condenser and the Optimal Treatment Measures

李富荣 1马涛 1金顺安2
扫码查看

作者信息

  • 1. 青海电研科技有限责任公司,青海 西宁 810008
  • 2. 国网青海省电力公司电力科学研究院,青海 西宁 810008
  • 折叠

摘要

针对大型调相机顶轴油系统的结构特点,结合某换流站 1 号调相机顶轴油系统调试过程中出现的异常问题,对调相机大轴顶起高度异常变化进行深入分析,通过分析润滑油温度和流量对大轴顶起高度的影响,从现场实际出发,提出相应的解决方法和预控措施,并提出顶轴油系统异常事件预控措施,为调相机顶轴油系统可靠运行提供参考.

Abstract

In view of the structural characteristics of the shaft oil system of a large-scale condenser regulator,combined with the abnormal problems occurred in the debugging process of the shaft oil system of No.1 condenser regulator in a converter station,based on the analysis of the influence of the temperature and flow rate of the lubricating oil on the lifting height of the main shaft of the camera,the corresponding solutions and pre-control measures are put forward,the measures to control the abnormal events in the pump oil system are put forward,which can provide reference for the reliable operation of the pump oil system of the condenser.

关键词

调相机/顶轴油/直流油泵/大轴顶起高度/预控措施

Key words

condenser/jack oil/DC oil pump/shaft jack height/pre-control measures