In view of the structural characteristics of the shaft oil system of a large-scale condenser regulator,combined with the abnormal problems occurred in the debugging process of the shaft oil system of No.1 condenser regulator in a converter station,based on the analysis of the influence of the temperature and flow rate of the lubricating oil on the lifting height of the main shaft of the camera,the corresponding solutions and pre-control measures are put forward,the measures to control the abnormal events in the pump oil system are put forward,which can provide reference for the reliable operation of the pump oil system of the condenser.
关键词
调相机/顶轴油/直流油泵/大轴顶起高度/预控措施
Key words
condenser/jack oil/DC oil pump/shaft jack height/pre-control measures