首页|多年冻土区太阳能制冷桩基主动冷却效果

多年冻土区太阳能制冷桩基主动冷却效果

扫码查看
桩基是多年冻土区最为常见的基础形式之一,降低桩基工程热扰动和提高桩基长期稳定性是冻土工程研究的重点.该文将太阳能制冷技术引入多年冻土区桩基工程,并开展主动冷却桩基现场试验与数值模拟研究.试验结果表明:温控桩壁的制冷温度可降至负温以下,运行3、10和30d的制冷半径分别达到0.65、1.24和1.5m以上;通过理论分析与数值反演估算温控桩的有效制冷功率约180W,制冷因数为0.9.模拟结果表明:制冷时长越大,桩壁温度振幅越大,稳定温度越低;制冷时长6、9和12h/d所对应的桩壁温度分别可降至-2.39、-3.48和-4.45 ℃;10a后的影响半径分别超出6.68、8.34和9.46m;温控桩服役10a后停止运行,桩周冻土仍可以在2~4a内处于低温稳定状态.
Active cooling effect of solar cooling piles in permafrost regions
[Objective]Pile foundations are one of the most commonly used foundation types in permafrost regions and are characterized by low thermal disturbance and high bearing capacity.Reducing engineering thermal disturbances and improving the long-term stability of pile foundations are key concerns in permafrost engineering.For friction pile foundations,bearing capacity mainly depends on the freezing strength at the interface between the pile and permafrost.Recently,global warming has increased,leading to an acceleration of the degradation of permafrost.It appears that the traditional design method relying solely on increasing pile diameter and length to improve pile bearing capacity is too conservative.Additionally,these methods do not have the bearing capacity reserves and may not be able to address the challenges of climate warming.Therefore,pile foundation settlement frequently occurs in permafrost regions.This study introduces solar cooling technology into permafrost engineering by proposing a solar cooling pile foundation.It comprises a solar power generation system,a vapor compression refrigeration system,and a concrete pile.This new structure actively cools the permafrost around the pile using a solar cooling system to protect the permafrost from climate warming effects.[Methods]In this study,onsite experiments were conducted using a model pile in the Qinghai-Tibet Plateau permafrost region.The model pile had a diameter and length of 0.16 and 4.5 m,respectively.We analyzed the actual cooling effects of the solar cooling pile,including the cooling temperature,cooling radius,and cooling power.Furthermore,we established a numerical model of the temperature field of solar cooling piles using finite element software(COMSOL Multiphysics).We conducted long-term cooling performance simulations under different cooling durations(6,9,and 12 h/d).[Results]The field test results demonstrated that the cooling temperature of the solar cooling pile sidewall could be reduced to a negative temperature,and the cooling radius reached 0.65,1.24,and 1.5 m after operating for 3,10,and 30 days,respectively.The adequate cooling power of the solar cooling pile was estimated to be approximately 180 W through theoretical analysis and numerical simulation.The coefficient of performance was approximately 0.9.The simulation results revealed that the longer the cooling duration is,the greater the amplitude of the pile-side temperature and the lower the stable temperature is.The pile temperature corresponding to cooling durations of 6,9,and 12 h/d were reduced to-2.39℃,-3.48℃,and-4.45℃,respectively;moreover,after ten years,the influence radius increased to 6.68,8.34,and 9.46 m,respectively.Even if the solar cooling pile stopped operating,the permafrost around the pile could remain in a stable low-temperature state for 2-4 years,providing ample time to maintain the solar cooling system.[Conclusions]The solar cooling pile can significantly reduce the permafrost temperature around the pile,effectively preventing permafrost degradation.In the future,it can be combined with remote control of the cooling temperature and duration,offering the prospect of achieving precise supplementary cooling for permafrost.This study provides a new method for designing and constructing piles in permafrost regions.

permafrost regionssolar cooling technologypile foundationground temperaturecooling effect

孙兆辉、刘建坤、陈浩华、游田

展开 >

中山大学土木工程学院,珠海 519082

南方海洋科学与工程广东实验室,珠海 519082

多年冻土区 太阳能制冷技术 桩基础 地温 制冷效果

国家自然科学基金面上项目国家自然科学基金重点项目

4217113041731281

2024

清华大学学报(自然科学版)
清华大学

清华大学学报(自然科学版)

CSTPCD北大核心
影响因子:0.586
ISSN:1000-0054
年,卷(期):2024.64(5)
  • 20