Improvement of the method for determining carbon content in aluminum electrolytic carbon slag
Referring to the method for determining alumina concentration in electrolyte,a detection method for determining the carbon content in aluminum electrolytic carbon slag was established through experiments,which involves dissolving fluorides with aluminum chloride,burning and weighing.Com-pared with the results measured by high-frequency infrared carbon analysis,this method is accurate,reliable and economical,which can effectively guide aluminum electrolytic production.