Along with the large-scale sulfur recovery unit,the relatively independent plant without acid gas pipe network faces the situation of low acid gas flow and low load operation con-ditions in the early stage of operation.This paper analyzes the problems existing in period of low load start-up,and puts forward a response scheme for the low load start-up of large-scale sulfur recovery unit with simulation calculation by combining with the operation of similar de-vices.