全面腐蚀控制2024,Vol.38Issue(10) :66-68.DOI:10.13726/j.cnki.11-2706/tq.2024.10.066.03

波长色散X射线荧光光谱仪的典型故障处理及注意事项

Typical Fault Treatment and Precautions of Wavelength Dispersive X-ray Fluorescence Spectrometer

林芳
全面腐蚀控制2024,Vol.38Issue(10) :66-68.DOI:10.13726/j.cnki.11-2706/tq.2024.10.066.03

波长色散X射线荧光光谱仪的典型故障处理及注意事项

Typical Fault Treatment and Precautions of Wavelength Dispersive X-ray Fluorescence Spectrometer

林芳1
扫码查看

作者信息

  • 1. 中国铝业股份有限公司连城分公司,甘肃 兰州 730335
  • 折叠

摘要

PW2403型X射线荧光光谱仪是原Philips(现马尔文帕纳科)公司的波长色散光谱仪,其具有分析速度快、灵敏度高、可分析元素范围宽的特点,样品可以是固体、粉末或液体等.通过多年的使用对此类型光谱仪可自行处理的典型故障及注意事项进行总结,确保高效率下的连续稳定运行.

Abstract

The PW2403 X-ray fluorescence spectrometer is a wavelength dispersion spectrometer from Philips(now Malvin Panaco)company.It has the characteristics of fast analysis speed,high sensitivity and wide range of elements that can be analyzed.The sample can be solid,powder or liquid.After many years of use,the typical faults and precautions that can be handled by this type of spectrometer are summarized to ensure continuous and stable operation with high efficiency.

关键词

X射线荧光光谱仪/故障处理/注意事项

Key words

X-ray fluorescence spectrometer/fault handling/precautions

引用本文复制引用

出版年

2024
全面腐蚀控制
中国工业防腐蚀技术协会

全面腐蚀控制

影响因子:0.278
ISSN:1008-7818
段落导航相关论文