首页|To Explore the Test Method of Eye Stimulation of Cosmetics by Zebrafish Embryo Method

To Explore the Test Method of Eye Stimulation of Cosmetics by Zebrafish Embryo Method

扫码查看
To study the feasibility of zebrafish model as an evaluation method for eye irritation of cosmetics,and to evaluate eye irritation of several common surfactants and wash products by this method.To construct a zebrafish eye stimulation model,stereomicroscope was used to observe the changes in eye morphology of zebrafish embryos to evaluate the stimulation of subjects.Two evaluation indexes were selected:pupil diameter and the ratio of pupil diameter to iris bandwidth.The results show that the ratio method of pupil diameter to iris bandwidth of zebrafish is insufficient.The experimental results of pupil diameter of zebrafish were highly coincident with those of chick embryo chorio-allantoic membrane.At the same time,the subject can inhibit the pupil diameter of zebrafish,and the pupil diameter is negatively correlated with the irritation of the subject.Therefore,the zebrafish model can be used in the evaluation of cosmetic eye irritation to provide rapid and efficient detection for product development.

eye irritationzebrafishpupil diameter

Lei Cuiting、Chen Laicheng、Yang Rongxin、Shen Guofeng、Zheng Muchuang、Xu Qitian、Ma Manhua、Chen Libing

展开 >

Guangdong North Indust Trial and Commercial Institutes of Green Skincare Co.,Ltd.,China

Guangdong Yalijie Fine Chemical Co.,Ltd.,China

2024

日用化学品科学(英文)
中国日用化学研究院有限公司

日用化学品科学(英文)

ISSN:2096-0700
年,卷(期):2024.9(4)