首页|超声造影及弹性成像技术对肝脏肿瘤良恶性的鉴别诊断价值分析

超声造影及弹性成像技术对肝脏肿瘤良恶性的鉴别诊断价值分析

扫码查看
目的:探究肝脏肿瘤良恶性应用超声造影(Contrast-enhanced ultrasound,CEUS)及弹性成像(Ultrasound elastography,UE)技术鉴别诊断价值.方法:选取 2020 年 8月至 2022 年 9 月于我院就诊的 80 例肝脏肿瘤患者作为研究对象.所有患者均行CEUS及UE检查.对比不同性质肝脏肿瘤患者CEUS检查血流灌注参数;以病理检查结果作为"金标准",分析对比CEUS、UE及联合检查结果;分析单项及联合检查诊断肝脏肿瘤性质的应用价值和一致性.结果:肝脏恶性肿瘤患者CEUS检查时始增时间、达峰时间、减退时间、持续强化时间均短于良性肿瘤,峰值强度高于良性肿瘤(P<0.05).不同检查方法下肝脏恶性肿瘤检出率对比无统计学差异.相比于CEUS、UE单项检查,联合检查灵敏度、准确度、阴性预测值均较高(P<0.05),一致性检验显示,CEUS、UE检查一致性均尚可(kappa值=0.521、0.676,P<0.05);联合检查一致性良好(kappa值=0.861,P<0.05).结论:肝脏肿瘤良恶性鉴别诊断中CEUS联合UE诊断应用价值较高,诊断准确度较高,且与"金标准"存在较强的一致性,同时还可清晰显示病灶处血流灌注情况.
Analysis of the value of contrast-enhanced ultrasound and elastography in the differential diagnosis of benign and malignant liver tumors
Objective:To explore the value of contrast-enhanced ultrasound(CEUS)and ultrasound elastography(UE)in the differential diagnosis of benign and malignant liver tumors.Methods:A total of 80 patients with liver tumors admitted to our hospital from August 2020 to September 2022 were selected as the study subjects.All patients underwent CEUS and UE examinations.the blood perfusion parameters of CEUS in different liver tumor patients were compared.Based on the gold standard(pathological examination result),the results of CEUS,UE and combined examination were compared and analyzed.The application value and consistency of single and combined examinations in diagnosing liver tumors was analyzed.Results:The time of onset,peak time,decline time and continuous enhancement time of patients with malignant tumors were shorter than those of benign tumors,and the peak intensity was higher than that of benign tumors(P<0.05).There was no statistically significant difference in the detection rate of malignant tumors in different examination methods.Compared with CEUS and UX,the sensitivity,accuracy and negative predictive value of the combined examination were higher(P<0.05),and the consistency of CEUS and UE was acceptable(kappa value=0.521,0.676,P<0.05).The consistency of the joint examination was better(kappa value=0.861,P<0.05).Conclusion:CEUS combined with UE has high application value,high accuracy in the diagnosis of liver tumor properties,and has a strong consistency with the gold standard,and can also clearly show the blood perfusion at the lesion.

Liver tumorsContrast-enhanced ultrasonographyUltrasound elastographyAccuracyConsistency

李兵

展开 >

郑州大学附属郑州中心医院超声科,河南 郑州 450000

肝脏肿瘤 超声造影检查 超声弹性成像 准确度 一致性

2024

四川生理科学杂志
四川省生理科学会

四川生理科学杂志

影响因子:0.575
ISSN:1671-3885
年,卷(期):2024.46(7)