Research on radiator performance of multifunctional demolition robot
The radiator plays an important role in the normal operation of multi-functional demolition robot.The whole radiator was modeled and the CFD software Fluent was used to analyze the heat dissipation performance of the radiator under different working conditions,and the distribution results of the velocity field and temperature field of the radiator were obtained.The results showed that,the heat dissipation performance of the radiator increased linearly with the increase of the flow rate of the external air,and decreased linearly with the increase of the external air temperature.The inlet velocity of heat fluid of the radiator had a significant impact on the heat dissipation effect.When the inlet velocity was greater than 0.4 m/s,the heat dissipation effect of the radiator changed slightly.Furthermore,the smaller the velocity of the heat fluid,the lower the temperature of the outlet fluid.The analysis results can provide data reference for the type selection of the radiator.
demolition robotradiatornumerical simulationenhanced heat transfer