首页|地下水源热泵采能区水热耦合模型研究

地下水源热泵采能区水热耦合模型研究

扫码查看
为合理安排地下水源热泵系统的抽灌井布局,利用地下水数值模拟方法,通过Visual MODFLOW软件中的SEAWATV4热运移模块,概化地下水温度场运移过程,建立了符合研究区域水文地质特征的水热耦合数值模型,采用不同的变量对合理井距离进行模拟研究,模拟得出在水温变幅不超过2℃的前提下,抽灌量300、800、1 500、2 500 m3/d的合理井距分别为26.5、53.0、80.0、106.0m,可知温度场的变化范围受井距和抽灌量影响明显并呈一定规律性,应根据水源热泵系统不同的抽灌量要求确定合理的抽灌井距离.
Research on Water-heat Coupled Model of Groundwater Source Heat Pump in Exploiting Energy Area
In order to solve the problem of rational distribution of the pumping wells in groundwater source heat pump system, groundwater numerical simulation method is adopted to describe migration process of groundwater temperature field by using heat migration module SEAWATV1 in Visual MODFLOW software. Water-heat coupled numerical model is established for study of hydrogeologic characteristics. The reasonable distance of the wells is simulated with different variable. On the premise of water temperature ranged no more than 2℃ , the reasonable well distance is 26. 5 m, 53. 0 m. 80. 0 m and 106. 0 m. respectively when the pumping or recharging capacity attains 300 m3/d,800 m3/d. 1 500 m3/d and 2 500 m3/d, respectively. Well distance and the amount of pumping and recharging have obviously impact on the change of temperature field and it has regularity. Therefore, reasonable distance of the wells should be determined in terms of different requirement of pumping and recharging wells in water source heat pump system.

water heat coupled mathematical modelgroundwater source heat pumpsimulationdistance of pumping well

杨武成、陈赫、李国正

展开 >

沈阳农业大学水利学院,辽宁沈阳110866

济南市邢佳渡引黄灌溉管理处,山东济南250100

水热耦合数学模型 地下水源热泵 模拟 抽灌井间距

沈阳市科技支撑基金资助项目

1091152-9-00

2012

水电能源科学
中国水力发电工程学会 华中科技大学 武汉国测三联水电设备有限公司

水电能源科学

CSTPCD北大核心
影响因子:0.525
ISSN:1000-7709
年,卷(期):2012.30(12)
  • 6
  • 2