首页|地下水源热泵不同布井模式下地下温度场变化模拟分析

地下水源热泵不同布井模式下地下温度场变化模拟分析

扫码查看
针对地下水源热泵抽水井与回灌井布局模式对地下温度场的影响,通过建立地下水流与温度的耦合模型,从抽灌井布置间距及抽灌井数量角度模拟分析了不同布井模式下地下水温度的变化趋势和热贯通发生的基本特性.结果表明,同类井间距对热贯通影响不显著,抽灌井间距对抽水温度及热贯通时间影响较大;从热贯通发生时间来看,抽灌井数量越多热贯通发生的时间越延迟,但从温度偏离度角度分析,系统长期运行后抽灌井数量对抽水温度偏离度影响不显著.
Simulation Analysis of Underground Temperature Field Changes of Groundwater Source Heat Pump under Different Layout of Wells
In view of the impact of layout of pumping wells and injecting wells of groundwater source heat pump on the underground temperature field,the coupling model between groundwater flow and temperature is established.From two aspects of the pumping and injecting wells' space and number,groundwater temperature variation trend and the basic characteristics of thermal penetrating are simulated and analyzed under different layout well modes.The results show that the similar wells distance have little impact on the thermal penetrating; the distance of pumping wells and injecting wells affect pumping temperature and thermal penetrating time significantly; the more number of pumping and injecting have,the more thermal penetrating time delay; for long term operation of the system,the number of pumping and injecting wells does not affect pumping temperature significantly.

coupling modellayout pattern of wellsthermal penetratinggroundwater source heat pump

张淑秘、高青

展开 >

长春建筑学院城建学院,吉林长春130607

吉林大学热能工程系,吉林长春130025

耦合模型 布井模式 热贯通 地下水源热泵

2013

水电能源科学
中国水力发电工程学会 华中科技大学 武汉国测三联水电设备有限公司

水电能源科学

CSTPCD北大核心
影响因子:0.525
ISSN:1000-7709
年,卷(期):2013.31(8)
  • 7
  • 4