首页|固相萃取-高效液相荧光法测定食品接触材料中双酚A、双酚F和双酚S的迁移量

固相萃取-高效液相荧光法测定食品接触材料中双酚A、双酚F和双酚S的迁移量

扫码查看
本研究建立了同时检测食品接触材料中双酚A、双酚F和双酚S的固相萃取-高效液相荧光的分析检测方法.根据食品类型,选择水性和油性食品模拟液进行迁移实验,浸提液经HLB固相萃取柱富集、浓缩、净化提取,采用甲醇-水作为流动相,荧光检测器检测.试验表明,在 0.10~100.0 μg/L质量浓度内线性关系良好,相关系数≥0.9997,双酚A、双酚F的检出限均为0.02 μg/L,双酚S的检出限为0.05 μg/L.测得 3种双酚类物质在5 种食品模拟液中加标回收率分别为80.2%~100.1%、83.3%~101.6%、77.6%~90.7%,相对标准偏差(RSD)为 1.7%~4.0%,方法符合研究要求.同时模拟液在 60℃浸提 30 min条件下测定了市售 4款食品接触材料的180 个样品,,结果在5 个样品中检测到双酚类物质迁移量.该方法灵敏、检测快速、结果准确,适用于食品接触材料中双酚A、双酚F和双酚S迁移量研究.
Solid-phase Extraction-HPLC Fluorescence Measurement of Food Contact Materials Bispheno A,F,and S Migration Detection
In this study,an analytical detection method was established for solid-phase extraction-HPLC fluorescence of bisphenol A,F and S in food contact materials.According to the type of food,the water and oily food simulation solution were selected for migration test.The extract was enriched,concentrated and purified by HLB solid phase extraction column,using methanol-water as the mobile phase and detected by fluorescence detector.The test showed that the linear relationship was good within the concentration of 0.10 to 100.0 μg/L,the correlation coefficient was 0.999 7,the detection limit of bisphenol A and bisphenol F was 0.02 μg/L,and the detection limit of bisphenol S was 0.05 μg/L.The recovery rate found that the three kinds of bisphenol in the five kinds of food simulation solution was 80.2%~100.1%,83.3%~101.6%,77.6%~90.7%respectively,and the relative standard deviation(RSD)was 1.7%~4.0%,and the method met the research requirements.At the same time,180 samples of 4 commercially available food packaging materials were measured in 60℃ extraction for 30min.Then,the migration of bisphenol was detected in 5 samples.This method is sensitive,rapid in detection and accurate in results,and is suitable for studying the migration amount of bisphenol A,bisphenol F and bisphenol S in food contact materials.

solid phase extractionhigh performance liquid phase fluorescencefood contact materialsbisphenolmigration

冯涛、邬玲玲

展开 >

杭州职业技术学院,浙江 杭州 310018

固相萃取 高效液相荧光法 食品接触材料 双酚类物质 迁移量

杭州职业技术学院科研项目

ky202404

2024

山西化工
山西省煤化工发展促进中心 山西省化工学会

山西化工

影响因子:0.293
ISSN:1004-7050
年,卷(期):2024.44(3)
  • 6