首页|双通道原子荧光法同时测定地表水中砷和汞含量

双通道原子荧光法同时测定地表水中砷和汞含量

扫码查看
建立了双通道原子荧光法同时测定地表水中砷和汞含量的方法.采用 0.2%(质量分数)氢氧化钾-2%(质量分数)硼氢化钾溶液为还原剂,5%(质量分数)盐酸-10%(质量分数)硫脲-10%(质量分数)抗坏血酸为介质液,双通道原子荧光仪在线监测.结果表明,砷元素在 1.0~20.0 μg/L、汞在 0.10~2.00 μg/L范围内线性关系良好,方法检出限分别为 0.125、0.0125 μg/L,加标回收率为 90.6%~109.0%,精密度RSD为1.48%~3.89%.该方法操作简便,同时测定地表水中砷和汞含量准确高效,适用性强.
Simultaneous Determination of Arsenic and Mercury in Surface Water by Dual Channel Atomic Fluorescence Method
The dual channel atomic fluorescence method for simultaneous determination of arsenic and mercury in surface water was developed.Using 0.2%potassium hydroxide and 2%potassium borohydride solution as reducing agent and 5%hydrochloric acid,10%thiourea and 10%ascorbic acid as medium,the on-line monitoring was carried out by double-channel atomic fluorometer.The results showed that the linear relationships were good in the range of 1.0~20.0 μg/L for arsenic and 0.10~2.00 μg/L for mercury.The detection limits were 0.125μg/L and 0.012 5μg/L,respectively.The recoveries were 90.6%~109.0%and the precision RSD was 1.48%~3.89%.The method is simple to operate,accurate,efficient and suitable for the determination of arsenic and mercury in surface water.