Working Principle and Equipment Maintenance of ABB Flatness Tester
This article elaborates on the working principles of the flatness roller,DTU,and sensor in the equipment composition of the flatness meter.It also introduces the DTU cooling,bearing labyrinth sealing,bearing lubrication,installation levelness,and sensor calibration process in equipment maintenance work.It also provides answers to possible problems that may arise in daily equipment maintenance.By explaining the equipment principle and maintenance,it can improve the beginner's understanding of the equipment and better maintain it.