Energy Efficiency Analysis of Saturated Waste Heat Steam Operation of OG System Based on Grey Correlation Degree
In view of the recovery and utilization of saturated waste heat steam in converters,there is a lack of energy efficiency evaluation methods in the existing OG system.A model for the energy efficiency analysis of converter saturated waste heat steam based on grey correlation analysis method was proposed,and simulation experiments were carried out on the Matlab platform based on the actual working data,and suggestions for improving the operation area of the OG system were obtained according to the experimental results,which was conducive to cost reduction,efficiency increase,energy saving and emission reduction.
OG systemsaturated waste heat steamgrey relevanceCRITIC method