首页|钢管混凝土叠合柱-H型钢梁外套筒式连接节点抗震性能和参数分析

钢管混凝土叠合柱-H型钢梁外套筒式连接节点抗震性能和参数分析

扫码查看
建立了钢管混凝土(concrete filled steel tube,CFST)叠合柱-H型钢梁外套筒式连接节点的有限元(finite element,FE)模型.考虑混凝土在循环荷载下的损伤以及钢材的包辛格效应,参照已有的试验数据研究了节点抗震性能及破坏机制,并对影响节点抗震性能的重要参数进行了分析.研究结果表明:有限元计算结果与试验结果吻合良好,节点滞回曲线饱满,延性系数介于3.17~4.19之间,等效黏滞阻力系数介于0.211~0.326之间;外套筒厚度会显著影响节点破坏形式,随着套筒厚度的增加节点域变形改善,破坏截面由节点外移至梁端截面;减小套筒宽厚比和增加套筒高度可以改善节点滞回性能,提高节点刚度;增加肋板厚度和高度与节点承载力和刚度呈正相关.为了保证外套筒式节点达到刚性节点要求,建议套筒宽厚比不大于25,套筒高度不小于套筒宽度的150%,加强肋板厚度不小于梁翼缘厚度,加强肋板高度不小于梁翼缘宽度的50%.
Seismic behavior and parametric analysis of CFST composite column to H-section steel beam joint with outer sleeve
A finite element(FE)model was established for a concrete filled steel tube(CFST)composite column connected to an H-section steel beam joint with an outer sleeve.Considering the damage to concrete under cyclic loading and the Bauschinger effect in steel and referencing existing experimental data,the seismic behavior and failure mode of the joint were examined throughout the process.Furthermore,important parameters influencing the joint's seismic performance were analyzed.The results indicated that the FE calculations were in good agreement with the experimental results,and the hysteretic curves of the joint were plump.The ductility coefficient was in the range of 3.17-4.19 and equivalent viscous damping coefficient was in the range of 0.211-0.326.The outer sleeve thickness significantly affected the failure mode of the joint.As the sleeve thickness in-creased,the deformation in the joint panel zone improved,and the failure section moved from the joint to the beam section.By reducing the width-to-thickness ratio and increas-ing the sleeve height,the hysteresis performance and stiffness of the joint were improved.The thickness and height of the reinforced ribs were positively correlated with the bearing capacity and stiffness of the joint.To ensure that the joint satisfies the stiffness require-ments,the width-to-thickness ratio of the sleeve should not exceed 25,the height of the sleeve should not be less than 150%of the width of the sleeve,and the thickness of the reinforced rib should not be less than 50%of the width of the beam flange.

concrete filled steel tube(CFST)composite columnouter sleeve type jointseismic performancefinite element(FE)analysisparametric analysis

李晨帆、杨锋

展开 >

上海大学力学与工程科学学院,上海 200444

钢管混凝土叠合柱 外套筒式连接节点 抗震性能 有限元分析 参数分析

2024

上海大学学报(自然科学版)
上海大学

上海大学学报(自然科学版)

CSTPCD北大核心
影响因子:0.579
ISSN:1007-2861
年,卷(期):2024.30(6)