上海纺织科技2024,Vol.52Issue(10) :25-28.

液质联用法测定化学纤维中的双酚A

Determination of bisphenol A in chemical fiber by LC-MS/MS

黄莉 邱星伟 任祥红 尹丽华 茅燕华
上海纺织科技2024,Vol.52Issue(10) :25-28.

液质联用法测定化学纤维中的双酚A

Determination of bisphenol A in chemical fiber by LC-MS/MS

黄莉 1邱星伟 1任祥红 1尹丽华 1茅燕华1
扫码查看

作者信息

  • 1. 江苏澄信检验检测认证股份有限公司,江苏江阴 214400
  • 折叠

摘要

研究不同前处理条件对化学纤维中双酚A含量测定的影响,建立高效液相色谱-串联质谱法(LC-MS/MS)测定化学纤维中双酚A含量的方法.以丙酮-二氯甲烷为溶剂,采用超声波萃取法提取样品,过滤后在LC-MS/MS上进行分析.试验结果表明,双酚A在10.0~200.0 μg/L范围内呈现良好的线性关系,相关系数为0.999,方法定量限为0.10mg/kg,加标回收率为80.63%~95.46%,相对标准偏差为2.74%~5.81%.该方法快速可靠、灵敏度高、稳定性好,适用于化学纤维中双酚A的测定.

Abstract

A high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for the determination of bisphenol A in chemical fibers is established by studying the influence of different pretreatment conditions on the determination of bisphenol A in chemical fibers.Using acetone dichloromethane as the solvent,the sample is extracted by ultrasonic extraction,filtered,and analyzed by LC-MS/MS.The results show that bisphenol A shows a good linear relationship in the range of 10.0~200.0 μg/L,the correlation coefficient is 0.999,the detection limit of is 0.10 mg/kg,the recoveries for spiked samples are 80.63%~95.46%,and the relative standard deviations range from 2.74%to 5.81%.The method is simple,rapid,stable and suitable for the determination of bisphenol A in synthetic fibers.

关键词

超声波萃取法/高效液相色谱-串联质谱法/双酚A/化学纤维

Key words

ultrasonic extraction/high performance liquid chromatography-tandem mass spectrometry/bisphenol A/chemical fiber

引用本文复制引用

出版年

2024
上海纺织科技
上海市纺织科学研究院

上海纺织科技

CSTPCD
影响因子:0.476
ISSN:1001-2044
段落导航相关论文