Failure Analysis and Solution Measures for Vibration Shutdown Fault of a Crude Oil Centrifuge in an Offshore Platform
The crude oil centrifuge on an offshore platform experienced abnormal vibration during operation,which affected the normal operation of the centrifuge and adversely affected the fuel oil treatment system.Unlike previous vibration caused by mechanical faults,the article analyzed the on-site process flow to identify the main causes of abnormal vibration in the oil centrifuge and developed a solution for the abnormal operation of the oil centrifuge.Through the successful implementation of the plan,the operating parameters of the oil centrifuge were restored to normal,while the fuel oil treatment system was stabilized.The relevant results provide technical support for the application of oil centrifuges in the field,and also provide relevant experience references for common faults that may occur in oil centrifuges.