大质量比较仪砝码自动定心装置基于"格栅交换"和"滚轮导轨配合"原理,解决了因秤盘面积大、加载时间长导致的偏载误差和数据漂移问题.从初始偏移距离、最大允许偏转角和定心误差三个方面分析了装置的性能和误差来源.根据JJF 1326-2011对装置进行了重复性、偏载误差和局部示值误差的校准测试,通过对比加装装置前后各项数据,验证了装置有效性,提升了测量的准确性和稳定性.

Abstract

The automatic centering device for large mass comparator weights is based on the principles of"grid exchange"and"roller guide rail matching",which solves the problems of eccentric load error and data drift caused by large weighing pan area and long loading time.The performance and error sources of the device were analyzed from three aspects:initial offset distance,maximum allowable deflection angle and centering error.According to JJF 1326-2011,the device was calibrated for repeatability,eccentric load error and local indication error.By comparing the data before and after the installation of the device,the effectiveness of the device was verified and the measurement quality was improved.accuracy and stability.

关键词

大质量比较仪/砝码/自动定心装置

Key words

large mass comparator/weight/automatic centering device