首页|Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating

Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating

扫码查看
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was first tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1 HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.

air source heat pump water heater(ASHPWH)cyclic heatingmicrochannelcondenser

李凡、陆高锋、丁云霄、郑春元、李斌、翟晓强

展开 >

College of Mechanical and Power Engineering,Shanghai Jiao Tong University,Shanghai 200240,China

Guangdong Midea HVAC Equipment Co.,Ltd.,Foshan 528311,Guangdong,China

国家自然科学基金

51776117

2024

上海交通大学学报(英文版)
上海交通大学

上海交通大学学报(英文版)

影响因子:0.151
ISSN:1007-1172
年,卷(期):2024.29(2)
  • 20