脱酮肟型硅酮密封胶中丁酮肟释放量的测定研究
Determination of Butanone Oxime Release in Deketoxime Type Silicone Sealant
袁骏1
作者信息
- 1. 上海建科检验有限公司,国家建筑工程材料质量检验检测中心,上海 201108
- 折叠
摘要
本研究采用顶空瓶作为脱酮肟型硅酮密封胶的硫化容器,在加入10 µL水和24 h的养护条件下,通过内标溶液在60 min内吸收释放出的丁酮肟,以气相色谱仪进行检测,内标法进行定量.该方法回收率为98.1%~104.2%,测定值的相对标准偏差(n=10)为1.84%.
Abstract
Using a headspace bottle as the vulcanization container for deketoxime type silicone sealant,under the condition of adding 10 µL of water and 24 hours of curing,the released butanone oxime was absorbed by internal standard solution within 60 minutes.The sample was detected by gas chromatography and quantified by the internal standard method.The recovery rate of this method was 98.1%-104.2%,and the relative standard deviation(n=10)of the measured value was 1.84%.
关键词
密封胶/丁酮肟/释放量/气相色谱仪/内标法Key words
sealant/butanone oxime/release/gas chromatography/the internal standard method引用本文复制引用
出版年
2024