Determination of trace phosphorus elements in nickel cobalt manganese ternary composite hydroxides by inductively coupled plasma method(ICP method)
A method for the determination of trace phosphorus in Ni-Co-Mn ternary complex hydroxide by inductively coupled plasma(ICP)was discussed in this paper.Phosphorus has a significant effect on the electrochemical performance of materials,so it is very important to measure its content accurately to optimize the performance and quality of batteries.The ICP method used in this paper is a highly sensitive and accurate measurement technology,which has excellent effect on the determination of trace elements in complex matrix.The results show that this method has the advantages of good linear relationship,high precision,high accuracy and little interference for the determination of phosphorus in Ni-Co-Mn ternary complex hydroxide,which proves its feasibility in practical application.