旁路放风问题分析及解决措施
Analysis and solution of bypass ventilation problem
黄海林 1王小文1
作者信息
- 1. 北京建筑材料科学研究总院有限公司,北京 100041
- 折叠
摘要
鉴于旁路放风系统存在旁路灰量过大,以及旁路灰中氯离子浓度偏低、熟料中氯离子超标、协同处置固废量不达标等问题,通过对设计数据与运行参数的综合分析,并结合热工标定、工艺计算、流场分析、物料检测,确定了问题的症结所在,并出具了调整方案.
Abstract
In view of the problems existing in bypass vent system,such as excessive amount of bypass ash,low chloride ion concentra-tion in bypass ash,excessive chloride ion in clinker,and substandard amount of collaborative waste disposal,the key points of the prob-lems were determined through comprehensive analysis of design data and operating parameters,combined with thermal diagnosis,pro-cess calculation,computational fluid dynamics,and material detection,the adjustment plan was provided.
关键词
旁路放风/协同处置/热平衡/CFD模拟/问题分析/解决措施Key words
bypass/co-processing/heat balance/computational fluid dynamics/problem analysis/solution引用本文复制引用
出版年
2024