生料125 μm和63 μm筛析试验测量系统分析
Measurement system analysis for 125 μm and 63 μm sieve residue of raw meal test
张媛媛 1向丛阳 1童昊 1高诗莹 1邵秋桐 1李瑞林 1刘继斌 1段亚军 2邹兴芳1
作者信息
- 1. 中国葛洲坝集团水泥有限公司,湖北 武汉 430070
- 2. 葛洲坝嘉鱼水泥有限公司,湖北 嘉鱼 437200
- 折叠
摘要
本文对多组生料样品进行125 μm和63μm负压筛析重复性和再现性检测,采用测量系统分析,比较了生料称样质量为25 g和10 g时的测量系统波动情况和3次重复筛析试验筛余物质量能否满足后续筛余物研磨制粉进行X射线衍射分析,最终确定了生料125 µm和63 μm负压筛析试验时适宜的称样质量分别为25 g和10 g.
Abstract
This paper conducts repeatability and reproducibility tests on multiple sets of raw meal samples using 125 μm and 63 μm negative pressure sieve analysis.The fluctuation of the measurement system was compared when the weight of the raw meal was 25 g and 10 g,and whether the quality of the sieve residue in three repeated sieve analysis tests could meet the requirements of subsequent sieve residue grinding and powder making for X-ray diffraction analysis.The appropriate sample weights for the negative pressure sieve analysis tests of 125 μm and 63 μm of raw meal were determined to be 25 g and 10 g,respectively.
关键词
生料/125/μm筛余/63/μm筛余/测量系统分析Key words
raw meal/residue/125 μm sieve residue/63 μm sieve residue/measurement system analysis引用本文复制引用
出版年
2024