In order to successfully apply health-care waste incineration facilities to mix incineration of medical waste,waste drugs and medicines,the vertical pyrolysis incinerator of a city's health-care waste incineration disposal center is used to conduct mix incineration tests to study the characteristics of medical waste,waste drugs and medicines,and its impact on the operating conditions of the vertical pyrolysis incinerator for health-care waste,and find the appropriate mix ratio into the furnace.After testing,it is determined that the 20%mix ratio would have no impact on the normal operation of the incinerator,and can provide technical reference for subsequent actual production,provided that the compatibility principle of mix ratio into the furnace is met.
关键词
医药废物/废药物及药品/掺烧/配伍原则
Key words
medical waste/waste drugs and medicines/mix incineration/compatibility principle