针对水产养殖中的控温需求,构建了PVT(Photovoltaic Thermal,光伏光热综合利用技术)系统与海水源热泵耦合系统.以 128.78 m3 不规则八边形养殖水池为需求对象,通过热负荷计算、设备选型、经济性分析和投资回收期考虑,验证了PVT系统与海水源热泵耦合系统的可行性.经济性分析表明,与传统的单一PVT集热系统辅助电加热系统相比较,该耦合系统仅需0.35 a即可实现动态投资回收.这证明了PVT系统与海水源热泵耦合系统在经济方面具有显著优势.不仅如此,还不断创新,提供了可持续性解决方案,经济性显著,也积极影响环境保护,具备较高的推广价值.研究对未来探索PVT系统与海水源热泵耦合应用具有重要的借鉴价值.
Performance of PVT System Coupled with Seawater Source Heat Pump
A PVT system and the seawater source heat pump coupling system was constructed to meet the temperature control requirements in aquaculture.The feasibility of the PVT system and seawater source heat pump coupling system was verified through heat load calculation,equipment selection,economic analysis,and investment payback period considerations,with an irregular octagonal aquaculture pool of 128.78 m3 as the demand object.Economical analysis shows that compared to traditional single PVT collector assisted electric heating systems,this coupled system only requires 0.35 a to achieve dynamic investment recovery.This proves that the PVT system and the seawater source heat pump coupling system has significant economic advantages.Not only that,but it also continuously innovates and provides sustainable solutions,with significant economic benefits and a positive impact on environmental protection,which has high promotion value.The research has important reference value for exploring the coupling application of PVT system and seawater source heat pumps in the future.

PVT systemseawater source heat pumpPVT coupled with seawater source heateconomical analysis

周义恒、张殿光、王旭阳、于宗君、马天燕

展开 >

大连海洋大学海洋与土木工程学院,辽宁大连 116023

辽宁省渔业装备工程技术研究中心,辽宁大连 116023

PVT系统 海水源热泵 PVT-海水源热泵耦合 经济性分析

2024

能源与节能
山西省能源研究会 山西省节能研究会

能源与节能

影响因子:0.561
ISSN:2095-0802
年,卷(期):2024.(2)
  • 11