实用肝脏病杂志2024,Vol.27Issue(4) :511-514.DOI:10.3969/j.issn.1672-5069.2024.04.005

一种新型超声显影导管声学特性研究

Acoustic performance of a newly knitted catheter with an improved ultrasonography visibility

冯谦 王睿 陈重
实用肝脏病杂志2024,Vol.27Issue(4) :511-514.DOI:10.3969/j.issn.1672-5069.2024.04.005

一种新型超声显影导管声学特性研究

Acoustic performance of a newly knitted catheter with an improved ultrasonography visibility

冯谦 1王睿 1陈重1
扫码查看

作者信息

  • 1. 610083 成都市 解放军西部战区总医院超声诊断科
  • 折叠

摘要

目的 探讨新型编织导管的超声显影能力.方法 使用电子显微镜观察、水听器声波信号检测、水槽导管环成像实验和活体猪肝脏实验,对比普通塑胶导管(n=10)与自制新型编织导管(n=10)在管壁结构、反射声波信号强度及在液体和活体动物肝脏组织超声显影能力方面的差异.结果 电镜下,新型编织导管管壁内可见与管体声阻抗不同的交叉成网的高分子材料纤维丝,纤维丝交叉点周围存在微气泡;水听器声波信号检测实验显示新型编织导管反射后接收到的基波和二次谐波信号分布更为均匀,角度依赖性小;在水槽导管环成像实验,新型编织导管管壁完整显示率为(91.9±1.2)%,管壁回声失落率为(4.0±0.7)%),多重反射伪像显示率为(4.3±0.9)%,均与普通塑胶导管存在显著性差异(P<0.01);活体猪肝脏实验显示新型编织导管超声回声强度、管壁连续性和尖端显影均优于普通塑胶导管.结论 新型编织导管具有更强的超声显影能力,可能具有较好的临床应用前景.

Abstract

Objective This study was conducted to investigate ultrasonography visibility of a newly knitted catheter.Methods Tube wall structure,reflected acoustic signal intensity and ultrasonography visibility in liquid and living animal liver tissue between conventional plastic catheter(n=10)and newly knitted catheter(n=10)were compared by through electron microscopy,hydrophone acoustic signal detection,flume catheter ring experiment and live pig liver implantation.Results Under electron microscope,interlaced polymer fibers were observed in the wall of the newly knitted tube,whose acoustic impedance values were different from those of the tube body,and microbubbles were also observed around the intersections of fibers;hydrophone detection experiments showed that the fundamental and second harmonic signals received by the newly knitted catheter were more evenly distributed and less angle dependent;in the catheter ring experiment,complete display rate was(91.9±1.2)%,echo loss rate was(4.0±0.7)%)and multiple reflection artifact display rate was(4.3±0.9)%,all much superior to conventional plastic catheter(P<0.01);in live pig liver in vivo,the echo intensity,wall continuity and tip development of the newly knitted catheter were much better than those of conventional plastic catheter.Conclusion The newly knitted catheter has stronger ultrasound visibility,which might be validated in clinical application.

关键词

超声显影/超声介入/编织导管/声学/体内

Key words

Ultrasound visibility/Ultrasound intervention/Knitted catheter/Acoustic performance/In vivo

引用本文复制引用

基金项目

全军计划生育专项课题(23JSZ20)

出版年

2024
实用肝脏病杂志
中华医学会安徽分会

实用肝脏病杂志

CSTPCD
影响因子:1.362
ISSN:1672-5069
段落导航相关论文