Application of Water Energy Saving Agent in Boiler of Catalytic Cracking Unit
The waste heat boiler of the catalytic cracking unit heats the flue gas by burning the gas,then heats the 4.2 MPa and 3.5 MPa saturated steam produced by the unit,among which the quality of the furnace water is directly related to the quality of the steam.The JHL120S series boiler water energy saving agent was tried out in catalytic cracking unit.Application data showed that the use of energy saving agent can not only improve the stability of furnace water quality,reduce the boiler water blowdown rate,achieve the purpose of energy saving and consumption reduction,but also effectively control the steam carrying,provide pre-film passivation protection for the whole water vapor system,and ensure the long-term stable operation of the unit.
catalytic crackingwaste heat boilerwater energy saving agentenergy saving and consumption reduction