首页|Wear dependent virtual flow rate sensor for progressing cavity pumps with deformable stator

Wear dependent virtual flow rate sensor for progressing cavity pumps with deformable stator

扫码查看
This contribution presents a novel wear dependent virtual flow rate sensor for single stage single lobe progressing cavity pumps.We study the wear-induced material loss of the pump components and the impact of this material loss on the volumetric efficiency.The results are combined with an established backflow model to implement a backflow calculation procedure that is adaptive to wear.We use a laboratory test setup with a highly abrasive fluid and operate a pump from new to worn condition to validate our approach.The obtained measurement data show that the presented virtual sensor is capable of calculating the flow rate of a pump being subject to wear during its regular operation.

BackflowProgressing cavity pumpVirtual sensorWear

Jens Müller、Sebastian Leonow、Johannes Schulz、Christian Hansen、Martin Mönnigmann

展开 >

Ruhr-Universität Bochum,Universitätsstraβe 150,Bochum,44801,Germany

SEEPEX GmbH,Scharnhölzstraβe 344,Bottrop,46240,Germany

Ministerium für Wirtschaft,Innovation,Digitalisierung und Energie des Landes Nordrhein-Westfalen

2024

石油科学(英文版)
中国石油大学(北京)

石油科学(英文版)

EI
影响因子:0.88
ISSN:1672-5107
年,卷(期):2024.21(2)
  • 1