根据国家标准GB/T 3810.3-2016中所述真空法来测定炻瓷砖吸水率,并列出整块样品所有位置吸水率检测值,并做出分析,探讨在实际检测过程中取样位置的偏差对检测结果的影响.
Abstract
According to the GB/T 3810.3-2016,determination of water absorption of stoneware tiles,and the water absorp-tion test values at all positions of the entire sample are listed and analyzed to explore the impact of sampling position devia-tion on the test results in the actual testing process.