首页|Ⅱ型接触网几何参数测量仪检定台架模拟支柱侧面限界复现值计算公式优化

Ⅱ型接触网几何参数测量仪检定台架模拟支柱侧面限界复现值计算公式优化

扫码查看
依据JJG(铁道)210-2020《接触网几何参数测量仪检定台架检定规程》,检定Ⅱ型接触网几何参数测量仪检定台架模拟支柱侧面限界复现值过程中,需利用公式计算模拟支柱侧面限界复现值。这些计算公式中,不仅需测量的参数多,计算复杂、计算量大,还会在检定结果中引入不确定度分量。在分析Ⅱ型接触网几何参数测量仪检定台架组成及其模拟支柱侧面限界复现值计算公式的基础上,研究简化模拟支柱侧面限界复现值计算公式。经验证,利用简化后的计算公式和JJG(铁道)210-2020 中的计算公式,计算得到的模拟支柱侧面限界复现值相等。利用简化公式,不仅减少了测量参数,测量参数更方便,计算过程更简单,还可以提高检定结果的准确度。
According to JJG(Railway)210-2020 Calibrater for measuring instrument for contact wire geometric parameter,in the process of verifying the recurrence value of the simulated mast gauge of the Ⅱ type calibrater for measuring instrument for contact wire geometric parameter,a formula needs to be used to calculate the recurrence value of the simulated mast gauge.These calculation formulas not only require a large number of parameters to be measured,involve complex and computationaly intensive calculations,but also uncertainty components in the verifica-tion results is introduced.On the basis of analyzing the composition of the Ⅱ type calibrater for measuring instrument for contact wire geometric parameter and the calculation formula for the recurrence value of the simulated mast gauge,the simplified calculation formula for the recurrence value of the simulated mast gauge is studied.After verification,using the simplified calculation formula and the calculation formula in JJG(Railway)210-2020,the recurrence value of the simulated mast gauge are equal.By using simplified formulas,not only can the measurement parameters be reduced,the measurement parameters are more convenient,the calculation process is simplified,but also can the accuracy of the calibration results be improved.

Measuring Instruments for Contact Wire GeometriyCalibraterMast GaugeCalculation Formula

熊鹰、陈晶京

展开 >

江西日月明测控科技股份有限公司,江西 南昌 330029

中国铁路南昌局集团有限公司科学技术研究所,江西 南昌 330002

接触网几何参数测量仪 检定台架 支柱侧面限界 计算公式

2024

铁道技术监督
铁道科学研究院

铁道技术监督

影响因子:0.244
ISSN:1006-9178
年,卷(期):2024.52(2)
  • 6