首页|半自动不能正常复原故障分析处理

半自动不能正常复原故障分析处理

扫码查看
通过逻辑分析半自动接车站、发车站到达复原故障现象,确认故障情况下两站控制台显示器表示灯点灯情况,观察故障情况下两站复原电路继电器动作情况,测试故障情况下两站信号机械室分线盘接收、发送电压数值、幅度,观察脉冲信号时间长度,进而充分运用信号集中监测回放故障现象,浏览比对故障情况下两站发送、接收负脉冲电压曲线状态、数据、幅度以及脉冲时间曲线状态、长度,达到精准判定故障范围,确认故障点,快速处理故障之目的。
Analysis and Processing of Failing to Recovery Normally for Semi-automatic Block
Through logical analysis of the phenomenon of recovery faults after train arrivals in a semi-automatic receiving station from a departure station,this paper confirms the lighting status of the indicator lights on the console displays of the two stations under fault conditions,observes the operation of the relays in the recovery circuits of the two stations during faults,tests the receiving and sending voltage values and amplitude of the distributing terminal boards in the signal mechanical rooms of the two stations during faults,and observes the time length of the pulse signal.This paper then makes full use of microcomputer to monitor and replay the fault phenomenon,browses and compares the voltage curve status,data,amplitude and pulse time curve status and curve lengths of the negative pulses sent and received by the two stations under the fault conditions,so as to accurately determine the fault range,confirm the fault point,and quickly deal with the fault.

logical analysissemi-automaticrecoverypulse length

王昱翔、窦丽明、王淑琴、郄佃举、尤玉淇、王继柱

展开 >

中北大学,太原 030051

国家能源投资集团有限责任公司神朔铁路分公司朔西站区,山西朔州 038500

中国铁路太原局集团有限公司大同电务段,山西大同 037000

逻辑分析 半自动 复原 脉冲长度

2024

铁路通信信号工程技术
北京全路通信信号研究设计院有限公司

铁路通信信号工程技术

影响因子:0.313
ISSN:1673-4440
年,卷(期):2024.21(6)
  • 20