Based on an actual brick-concrete structure as the research object,firstly,the reasons of the tilt of the building were analyzed.Secondly,considering factors such as construction feasibility and controllability,surrounding environmental impact,and economic indicators,the jack-up method was selected for inclination rectification.Before the rectification,the foundation and bottom wall were reinforced to ensure structural safety during the correction process.After the rectification,the gaps in the foundation wall were effectively connected to prevent re-tilting.At last,reinforcement measures were taken to reinforce the upper load-bearing wall by chiseling open brick joints and inserting steel bars,which ensured the safety of the structure without reducing the net usable area of the room.
Jack-up methodInclination rectificationPrevention from re-tiltingChiseling open brick joints and inserting steel bars