首页|NM500钢板冷弯断裂原因分析

NM500钢板冷弯断裂原因分析

扫码查看
某厂厚度为10 mm的NM500钢板在冷弯试验过程中出现断裂.为研究其断裂原因,通过对弯曲试验断裂钢板与合格的钢板进行冷弯工艺参数、拉伸性能、显微组织及夹杂物类型、断口形貌、能谱检测对比综合分析其冷弯断裂原因.结果表明:钢中大尺寸的MnS和不规则形态、团聚的TiN夹杂物破坏了钢板连续性,在冷弯过程中出现微裂纹,随着应力增大微裂纹扩展,最终导致钢板冷弯断裂.
Analysis of cold bending fracture of NM500 steel plate
Fracture occurred for a 10 mm NM500 steel plate in the cold bending test process.In order to study the cause of fracture,the bending test fracture steel plate and qualified steel plate were used for comprehensive analysis including cold bending process parameters,tensile properties,microstructure and inclusions type,fracture morphology,and energy spec-trum detection comparison.The results showed that the large size MnS inclusions and agglomerated TiN inclusions with ir-regular morphology destroyed the continuity of the steel plate,and the micro-cracks appeared in the cold bending process.With the increase of stress,the micro-cracks expanded and finally led to cold bending fracture of the steel plate.

NM500cold bending fractureMnS and TiN inclusion

陈以荟、曾智中、黎建东、王世茹、林森明

展开 >

广西盛隆冶金有限公司,广西防城港 538000

NM500 冷弯断裂 MnS和TiN夹杂

2024

物理测试
中国钢研科技集团有限公司

物理测试

影响因子:0.363
ISSN:1001-0777
年,卷(期):2024.42(4)