物理学报2024,Vol.73Issue(19) :103-108.DOI:10.7498/aps.73.20241061

长距离泵浦-探测系统的阿秒精度锁定

Attosecond delay locking of large arm pump-probe system

王柯俭 滕浩 邢笑伟 董朔 曹凯强 江昱佼 赵昆 朱江峰 刘文军 魏志义
物理学报2024,Vol.73Issue(19) :103-108.DOI:10.7498/aps.73.20241061

长距离泵浦-探测系统的阿秒精度锁定

Attosecond delay locking of large arm pump-probe system

王柯俭 1滕浩 2邢笑伟 3董朔 4曹凯强 5江昱佼 6赵昆 7朱江峰 6刘文军 3魏志义2
扫码查看

作者信息

  • 1. 西安电子科技大学光电工程学院,西安 710071;中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190
  • 2. 中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190;中国科学院大学物理科学学院,北京 100049;松山湖材料实验室,东莞 523808
  • 3. 中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190;北京邮电大学理学院,北京 100876
  • 4. 中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190;中国科学院大学物理科学学院,北京 100049
  • 5. 中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190
  • 6. 西安电子科技大学光电工程学院,西安 710071
  • 7. 中国科学院物理研究所,北京凝聚态物理国家实验室,北京 100190;松山湖材料实验室,东莞 523808
  • 折叠

摘要

随着超快科学和阿秒脉冲技术的发展,基于孤立阿秒脉冲的泵浦-探测系统由于能实现对电子动力学的时间分辨测量,已成为人们开展阿秒超快过程研究不可或缺的关键技术.但要获得稳定可靠的泵浦-探测信号,需要保证泵浦与探测光之间阿秒级的高精度同步,较大的抖动将会导致信号产生弥散、甚至被淹埋在噪声中,从而无法获得真实的物理图像.由于阿秒脉冲从产生到应用终端之间的距离通常较长,要实现阿秒时间分辨,就必须对阿秒光脉冲与泵浦光进行阿秒量级的延时锁定.针对这一问题,本文发展了一种新型的双层光路系统,通过对获得的干涉条纹进行快速傅里叶变换,将获得的时间抖动量反馈给压电平移台实时补偿光程漂移,实现了泵浦光与探测光之间阿秒量级的同步锁定.应用该方案到光路长度从1-10 m的阿秒泵浦探测系统,得到了锁定精度分别从7.64-31.76 as的结果,分析表明系统延时误差与距离呈严格的线性关系,决定数R2=0.96.本研究工作表明,使用小型干涉仪可实现对大科学装置中长距离阿秒泵浦探测系统的锁定精度进行快速检测,这对如非共线阿秒条纹相机、时间分辨光电子能谱仪、相干合成等应用具有一定的参考意义.

Abstract

With the development of ultrafast science and attosecond laser technology,the pump-probe system based on isolated attosecond laser pulses is a key to attosecond science,which will be used to study electronic dynamics on an attosecond time-scale.To obtain stable and reliable signals,it is necessary to ensure ultra-stable and ultra-accurate synchronization.Any timing jitter can cause signal to disperse or get buryied in noise,making it impossible to obtain the true physical mechanism.Based on the above,the delay between pump laser pulse and probe laser pulse must be controlled with an attosecond time resolution.In this work,a dual-layer system is developed to achieve high-precision synchronization locking.To ensure that both layers have the same time jitter,we design an adapter to secure the elements placed during installation.Timing jitter is obtained by shaking interference fringes through fast Fourier transformation,and can be calculated in several ms.Then error signals are fed back to the PZT stage in order to compensate for real-time optical path drift.Through such a design,a time-delay accuracy of 7.64 as to 15.53 as is realized,which is linearly related to the interferometer arm length ranging from 1 m to 5 m,with an R2 of 0.96.Moreover,the error between the experimental result of arm length of 8 m and 10 m and the result fitted with the above data is less than 3 as.These results show that using a small interferometer can achieve the fast detection of the time-delay accuracy of long-arm attosecond pump-probe detection system in large scientific instrument,which is of great significance in guiding ther applications such as in non-collinear attosecond streaking spectroscopy,time-resolved photoelectron spectroscopy,and coherent synthesis.

关键词

超快科学/泵浦探测系统/延时锁定

Key words

ultrafast science/pump-probe system/delay locking

引用本文复制引用

基金项目

国家重点研发计划(2022YFA1604200)

国家自然科学基金(12034020)

出版年

2024
物理学报
中国物理学会,中国科学院物理研究所

物理学报

CSTPCDCSCD北大核心
影响因子:1.038
ISSN:1000-3290
参考文献量21
段落导航相关论文