建立了电感耦合等离子体质谱法(ICP-MS) 测定 PM2. 5 中痕量金属元素的方法.电热板湿法消解, 以 Y/Bi/In元素作为内标校正干扰,ICP-MS 测定 PM2. 5 中痕量金属元素.该方法线性良好, 相关系数为 0. 999 9, 方法的检出限为 0. 11 ~ 36. 1 mg/m3,方法的精密度和准确度良好,相对标准偏差在 8. 3% ~ 19. 4% 之间,平均回收率为 85. 0% ~ 95. 5%.整个方法简单、 快速和准确,可用于分析 PM2. 5 中的金属元素.
A method for the determination of trace metal elements in PM 2. 5 by inductively coupled plasma mass spectrometry(ICP-MS) was developed. Wet digestion, the interference was corrected by using Y/Bi/In element as internal standard, and trace metal elements in PM 2. 5 were determined by ICP-MS. The method has good linearity and the correlation coefficient is 0. 999 9. The detection limits of the method were between 0. 11 and 36. 1 mg/m3. The precision and accuracy of the method were good. The relative standard deviations were between 8. 3% and 19. 4%, and the average recoveries ranged from 85. 0% to 5. 5%. The method was simple, fast and accurate and can be used to analyze trace metal elements in PM2. 5.