首页|喷雾蒸发冷凝对空调性能影响的实验研究

喷雾蒸发冷凝对空调性能影响的实验研究

扫码查看
为降低空调机组高温工况能耗、提高机组能效比,提出将喷雾蒸发冷凝技术应用于空调冷凝器的方法.首先,理论计算喷雾所需水流量,采用喷嘴对空调V型冷凝器降温;然后,在标准焓差实验室中进行喷嘴与冷凝器不同距离、不同喷射角度以及间歇喷雾的相关实验,并分析喷雾在不同工况下的节能效果.结果表明:将喷雾蒸发冷凝技术应用于冷凝器具有较好的节能效果.喷嘴与冷凝器最佳安装距离为40 cm、喷嘴最佳喷射角度为60°,在室内干球温度37 ℃,室外干/湿球温度35/27 ℃时,机组能效比由4.0提升至4.89,能效提高率22.2%,并且能效提高率随室外温度降低而下降,喷雾蒸发冷凝技术更适用于高温地区,可为喷雾蒸发冷凝技术在空调冷凝器应用提供参考.
Experimental study on the effect of spray evaporative condensation on air conditioning performance
In order to reduce the energy consumption of air conditioning units in high-temperature working conditions and improve the energy efficiency ratio of the units,this study proposes to ap-ply the spray evaporative condensation technology to air conditioning condensers.Firstly,the wa-ter flow required for spraying was theoretically calculated,and the nozzles were used to cool the V-type condenser of air conditioner;then,in the standard enthalpy difference laboratory,the rele-vant experimernts of different distances between the nozzles and the condenser,different injection angles and intermittent spray were carried out,and the energy-saving effect of spray under differ-ent working conditions were analyzed.The results show that the spray evaporation condensation technology applied to the condenser has a better energy-saving effect.The optimal installation dis-tance between the nozzle and condenser is 40 cm,the optimal spray angle of the nozzle is 60°,in the indoor dry bulb temperature of 37 ℃,outdoor dry/wet bulb temperature of 35/27 ℃,the en-ergy efficiency ratio of the unit increases from 4.0 to 4.89,the energy efficiency improvement rate is 22.2%,and the energy efficiency improvement rate decreases with the drop of the outdoor tem-perature.The technology is more suitable for high-temperature areas.It can provide a reference for the application of the technology in air conditioner condenser.

spray evaporative condensationnozzle arrangementcondensing pressurecompres-sion ratioenergy efficiency ratio

黄翔、胡建、苏林、褚俊杰、颜利波、杨柳、王欣

展开 >

西安工程大学城市规划与市政工程学院,陕西西安 710048

广东美的暖通设备有限公司,广东佛山 528311

喷雾蒸发冷凝 喷嘴布置 冷凝压力 压缩比 能效比

深圳市科技研发可持续发展项目

KCXFZ20201221173409026

2024

西安工程大学学报
西安工程大学

西安工程大学学报

CSTPCD
影响因子:0.473
ISSN:1674-649X
年,卷(期):2024.38(5)