首页|方形动力电池组多风道热管理研究

方形动力电池组多风道热管理研究

扫码查看
针对传统风冷式电池热管理系统的散热能力不足、电池组整体均温性较差的问题,提出了一种分层多风道风冷式冷却方法,采用挡风板将单风道系统分割为多风道系统,建立了多风道动力电池热管理系统.通过实验方法测量了钴酸锂电池的放电温升以及电阻与放电深度的关系,并针对多风道电池热管理模型进行了数值计算研究.结果表明,三风道U型热管理系统的散热效果优于其他热管理系统.当冷却空气流速为0.5 m/s时,三风道U型电池热管理系统的最高温度降低8.4 K,最大温差减小12.4 K,电池组均温性提高.当冷却空气流速为5m/s时,三风道U型电池热管理系统的最高温度及温差均可以降低5.3 K.使电池组的最高温度和最大温差保持在合理范围内.
Study on multi-channel air cooling thermal management of prismatic power battery pack
In this paper,a multi-channel air cooling method has been proposed for the prismatic power battery ther-mal management system by separating the original one channel into several using windshield,enhancing the heat dissipation capacity of the traditional air cooling system,improving the temperature uniformity of the battery pack.In this study,the temperature increment of the lithium cobalt oxide battery caused by the discharging and the rela-tionship between the electric resistance and the depth of discharge(DOD)have been observed experimentally,fur-thermore,the cooling characteristics of the multi-channel thermal management system has been studied numerically.As a result,the heat dissipation effectiveness of 3 channels U type cooling system has been found is superior to oth-ers.For instance,the maximum temperature and the maximum temperature difference decrease 8.4 K and 12.4 K respectively for the 0.5 m/s air flow velocity,whereas for the case of 5 m/s air flow velocity,both the above 2 val-ues decrease 5.3 K.The maximum temperature and the maximum temperature difference of the battery pack main-tain a value in a reasonable range.

prismatic power batteryair coolingbattery packmulti-channel thermal management

白晓辉、高渊博、张玉碧、刘存良

展开 >

西北工业大学 动力与能源学院,陕西 西安 710129

方形动力电池 风冷 电池包 多风道热管理

国家自然科学基金

52006179

2024

西北工业大学学报
西北工业大学

西北工业大学学报

CSTPCD北大核心
影响因子:0.496
ISSN:1000-2758
年,卷(期):2024.42(2)
  • 20