贫液水冷器换热管泄漏失效分析
Leakage failure analysis of heat exchanger tubes of barren liquor water cooler
高洪英1
作者信息
- 1. 上海寰球工程有限公司 上海徐汇 200030
- 折叠
摘要
针对某企业运行装置中溶剂贫液水冷器换热管泄漏,导致循环水碱度较高的现象,通过对换热管泄漏情况进行分析,确定了泄漏的原因,提出防止此类换热管泄漏的建议.
Abstract
In response to the phenomenon of high alkalinity of circulating water due to the solvent leakage of heat exchanger tube of barren liquor water cooler in the operating device of an enterprise,the leakage situation of heat exchanger tube is analyzed,the cause of leakage is determined,and the suggestions for preventing the leakage of this kind of heat exchanger tube are proposed.
关键词
换热管/泄漏/原因分析Key words
heat exchanger tube/leakage/cause/analysis引用本文复制引用
出版年