首页|变换装置脱盐水换热器腐蚀原因分析

变换装置脱盐水换热器腐蚀原因分析

Analysis of corrosion causes of desalinated water heat exchanger in conversion device

扫码查看
CO变换汽提塔出气冷却换热器与脱盐水换热进行降温,在运行过程中此换热器经常出现泄漏等问题.本文分析了汽提塔出气各种成分对换热管材质的腐蚀机理,并根据其特点提出相应的处理措施.
The cooling heat exchanger for the outlet of the CO conversion stripping tower,which exchanges heat with desalinated water for cooling,The heat exchanger often leaks and other problems during operation.This article analyzes the corrosion mechanism of various components in the exhaust gas of the stripping tower on the material of heat transfer tubes,and proposes corresponding treatment measure based on their characteristics.

desalinated water heat exchangercorrosionreasonsmeasures

韩帅、赵林涛、崔玉彪、蒋永刚

展开 >

江西心连心化学工业股份有限公司 江西九江 332000

脱盐水换热器 腐蚀 原因 措施

2024

氮肥技术
全国化工合成氨设计技术中心站

氮肥技术

影响因子:0.104
ISSN:
年,卷(期):2024.45(5)