首页|气相色谱-串联质谱法测定到手香中四聚乙醛残留量

气相色谱-串联质谱法测定到手香中四聚乙醛残留量

扫码查看
建立气相色谱-串联质谱(GC-MS/MS)法检测到手香中四聚乙醛的残留量.到手香样品粉碎后采用1%乙酸水溶液+乙腈(体积比10∶15)提取,经HLB SPE固相萃取小柱净化,DB-5MS色谱柱分离,外标法定量.结果表明,在质量浓度0.01~1.00 mg/L,方法线性关系良好,相关系数为0.999 7.在质量分数0.006~0.060 mg/kg,方法平均回收率为88.13%~93.35%,相对标准偏差(RSD)为0.81%~2.19%(n=6).四聚乙醛检出限为0.002 mg/kg,定量限为0.006 mg/kg.此方法简便快捷、灵敏度高、稳定性好,适用于到手香中四聚乙醛残留量的检测.
Determination of metaldehyde residue in patchouly by GC-MS/MS
A method for the determination of metaldehyde residues in patchouly was developed by GC-MS/MS.The crushed samples were extracted with acetic acid 1%aqueous solution and acetonitrile(volume ratio of 10:15),purified by HLB SPE column,performed on DB-5MS column,and quantified by external standard method.The results showed that at the concentration of 0.01-1.00 mg/L,the linear relationship was good,and the correlation coefficient was 0.999 7.At the concentration of 0.006-0.060 mg/kg,the average recoveries were 88.13%-93.35%,the relative standard deviation ranged from 0.81%to 2.19%(n=6).The limit of detection(LOD)and the limit of quantification(LOQ)were 0.002 mg/kg and 0.006 mg/kg,respectively.The method was simple,rapid,sensitive,and suitable for the deteremination of metaldehyde residues in patchouly.

GC-MS/MSmetaldehydepatchoulyresiduedetection

于艳丽、刘雨田、李婧

展开 >

上海杉达学院,上海 201209

气相色谱-串联质谱 四聚乙醛 到手香 残留 检测

上海"晨光计划"项目

18CGB02

2024

现代农药
江苏省农药协会 江苏省农药研究所股份有限公司 江苏省农药科技信息站

现代农药

CSTPCD
影响因子:0.471
ISSN:1671-5284
年,卷(期):2024.23(4)