自动喷水灭火局部应用系统的设置要求及工程应用探讨
The Setting and Engineering Application of Locally Applied Automatic Fire Sprinkler System
张涛1
作者信息
- 1. 邯郸市消防支队,河北 邯郸 056001
- 折叠
摘要
设置自动喷水灭火局部应用系统,必须充分考虑流量对整个消防系统的影响,需要校核水池容积、供水管径等技术参数.本文结合某工程实例,对自动喷水灭火局部应用系统参数进行计算,并阐述了其设置要求,为设计及审图人员提供了参考依据.
Abstract
For the specifications of local applied automatic sprinkler system being added in GB 50084-2017, Code of Design for Sprinkler Systems, the influence of its flow rate on the whole fire system should be fully considered and the technical parameters such as the volume of fire pool and the diameter of water supply pipe should be checked when setting up the system. Combining with an engineering case the author stated the setting requirements of the system parameters to provide reference for design and review personnel and ensure the reliability of fire water supply.
关键词
自动喷水/局部应用/安全/建议Key words
automatic sprinkler/local application/system parameters/suggestion on setup引用本文复制引用
出版年
2018