首页|皮带秤校准的溯源标准问题

皮带秤校准的溯源标准问题

扫码查看
本文分析论述了皮带秤校验过程应注意的一个重要验证参数——皮带测速信号参数,它是确定皮带秤校准溯源的一个关键信息数据,其准确与否直接影响最终校验结果的应用.皮带秤的运行使用准确与否与皮带秤秤架结构、传感器力值转换精度有其直接关系,但校验皮带秤时,运行皮带的带速决定"校验基准值"的溯源,溯源标准会直接影响校验结果判定,这是十分明确的.
Traceability Standards for Calibration of Belt Scales
This article analyzes and discusses an important validation parameter that should be paid attention to during the cali-bration process of belt scales-the belt speed measurement signal parameter.It is a key information data for determining the calibration traceability of belt scales,and its accuracy directly affects the application of the final calibration results.The accu-racy of the operation and use of the belt scale is directly related to the structure of the belt scale frame and the accuracy of sen-sor force value conversion.However,when verifying the belt scale,the speed of the running belt determines the traceability of the"calibration reference value",and the traceability standard will directly affect the judgment of the calibration results,which is very clear.

belt scalecalibrationbelt speed measurement

张书文、孟飞

展开 >

新疆八一钢铁股份有限公司设工部,新疆 乌鲁木齐 830022

皮带秤 校准 皮带测速

2024

新疆钢铁
新疆维吾尔自治区金属学会

新疆钢铁

影响因子:0.081
ISSN:1672-4224
年,卷(期):2024.(4)