首页|智能型浮筒液位(界位)变送器现场调试常见问题及处理方法

智能型浮筒液位(界位)变送器现场调试常见问题及处理方法

扫码查看
以LC3244LD型变送器为例,介绍了智能型浮筒液位(界位)变送器在生产装置中的工作原理和安装方法,阐述了浮筒液位(界位)变送器的现场安装步骤及调试过程,并对调试过程中可能遇到的常见问题及设置方法进行了说明.针对使用过程中出现的故障提出了具体的解决方案,旨在确保智能型浮筒在乙烯装置中正常运行.
Common Problems and Solutions for On-site Debugging of Intelligent Float Level(Interface)Transmitter
Taking the LC3244LD transmitter as an example,the working principle and installation method of the intelligent float level(boundary)transmitter in the production equipment is introduced.The on-site installation steps and debugging process of the float level(boundary)transmitter are explained,and common problems that may be encoun-tered during the debugging process and processing methods are explained.Specific solutions have been proposed for the faults that occur during use,aiming to ensure the normal operation of the intelligent float in the ethylene plant.

float level transmitterfloat interface transmitterintelligentfault phenomenonheavy mediumlight medium

张晶晶、胡文萍、刘建冬、刘籽晨、过磊

展开 >

新疆独山子石化公司信息网络公司,新疆克拉玛依 833699

浮筒液位变送器 浮筒界位变送器 智能型 故障现象 重介质 轻介质

2024

仪表技术
上海市仪器仪表学会,上海仪器仪表研究所等

仪表技术

影响因子:0.217
ISSN:1006-2394
年,卷(期):2024.(5)