电气化铁路接触网绝缘性能的实践研究
An Empirical Study of the Insulation Property of the Contact Line of Electrified Railways
摘要
结合同煤集团四台沟电气化铁路110 kv牵引变电所及接触网供电设备故障跳闸率对煤矿电气化铁路定量装车点的接触网设备结构及污染情况进行了系统分析,研究出了提高重污区接触网设备绝缘性能的技改方法,并附注实践取得了良好的效果。
Abstract
By analyzing the malfunction tripping rate of the power supply equipment in Silaogou for the 110kv hauling transformation sub-station,and the structure of and pollution state of the contact line of the quantitative load spot,technical measures to improve
关键词
电气化铁路/接触网/定量装车点/绝缘性能Key words
electrified railway/contact line/quantitative load spot/insulation property引用本文复制引用
出版年
2011