Analysis on Reason and Preventive Measure for the Falling Off of External Insulation Layer on Building Exterior Wall
Based on the project in a college,this paper analyzes the reasons for the falling off of the external insulation layer on the exterior wall,and expounds the preventive measures for the falling off of the external insulation layer on the building exterior wall,including replacing the insulation form,strengthening the insulation layer,eliminating the heat bridge effect,and adopting the non-cavity fully adhesive structure,so as to enhance the reliability of the insulation system on the building exterior wall,give full play to the insulation function,and avoid the falling off of the insulation board,so as to provide a safe and comfortable indoor and outdoor environment for teachers and students.
building exterior wallexternal insulation layerheat bridge effectnon-cavity fully adhesive structure