Analysis of the Key Points of Reverse Osmosis Equipment in Use
Reverse osmosis membrane technology has been more widely used in indus-try in recent years,but in the actual application process,there are often problems such as ultra-high-pressure operation of reverse osmosis equipment,frequent rupture of explosion-proof membranes,short operating cycles of reverse osmosis equipment,and difficulties in cleaning reverse osmosis equipment.To solve those problems,combined with the actual op-eration of the desalination station,by taking a series of measures such as setting the high and low pressure protection of high pressure pump,valve switching delay,incoming water quality control,selecting suitable bactericidal agent,and setting the appropriate temperature of the cleaning solution,the efficient and stable operation of the reverse osmosis equipment is effectively ensured.
water treatment facilityreverse osmosis equipmentchemical cleaningback pressure of produced waterdifferential pressure between sections