首页|烟气连续监测系统在加热炉的运用探讨

烟气连续监测系统在加热炉的运用探讨

扫码查看
描述了烟气连续监测系统在加热炉上的综合运用.为实现加热炉烟气中气态污染物(SO2、NOX、O2)和颗粒物浓度,温度、压力、流量和湿度等参数在操作台上在线监测,通过在烟气分析室内新增S7-300 PLC系统建立通讯,实现烟气连续监测数据实时传输至上位机,在加热炉燃烧系统新增画面上显示及智能预警、报警,实现与加热炉的工艺燃烧的联锁控制.
Discussion on Application of Flue Gas Continuous Monitoring System in Heating Furnace
This paper describes the comprehensive application of flue gas continuous monitoring system in heating furnace.In order to realize the online monitoring of gaseous pollutants(SO2,NOX,O2)and particulate matter concentration,temperature,pressure,flow rate and humidity in the flue gas of the heating furnace on the operating table,a new S7-300 PLC system is added to the flue gas analysis room to establish communication.As a result,the real-time transmission of flue gas continuous monitoring data to the host computer is realized,and displaying,intelligent early warning and alarming on the new-added screen of the heating furnace combustion system are realized,so as to realize the interlocking control with the process combustion of the heating furnace.

heating furnaceflue gas continuous monitoring systemintelligent early-warningalarm

黎永恒

展开 >

福建三钢闽光股份有限公司设备动力部,福建 三明 365000

加热炉 烟气连续监测系统 智能预警 报警

2024

冶金设备管理与维修
鞍山钢铁集团公司

冶金设备管理与维修

影响因子:0.029
ISSN:1006-5644
年,卷(期):2024.42(4)