热电高压锅炉给水泵变频器电气节能改造可行性分析
Feasibility Analysis of Electrical Energy-saving Transformation for the Frequency Converter of the Feedwater Pump in a Thermoelectric High-pressure Boiler
陈庆波 1周斌2
作者信息
- 1. 云南天安化工有限公司, 云南 安宁 650106
- 2. 云南云聚能新材料有限公司, 云南 安宁 650106
- 折叠
摘要
为了降低水泵、管道的能量损耗,在确保供水量的同时实现节能,拟利用闲置的高压变频器,改造后用于高压锅炉给水泵,实现节能目的.对电机、变频器、电缆等进行了计算分析,为热电装置的电气部分的节能改造提供了技术支撑.
Abstract
In order to reduce the energy loss of water pumps and pipelines and achieve energy conservation while ensuring water supply,it is planned to use idle high-voltage frequency converters and transform them into high-pressure boiler feedwater pumps to achieve energy-sav-ing goals.The calculation and analysis of motors,frequency converters,cables,etc,have provided technical support for the energy-saving trans-formation of the electrical part of the thermoelectric device.
关键词
热电高压锅炉/给水泵/变频器/节能/电机Key words
thermoelectric high-pressure boiler/water supply pump/frequency converter/energy saving/electrical machinery引用本文复制引用